Name |
Description |
Code value |
LL |
Lateral line.
-- Description --
A <i>lateral line </i>is a small-diameter pipe that runs from the main line to the customer premises. <i>LateralLine</i><i> </i>is a concrete class. The types of lateral lines are Combination, Commercial, Domestic, Fire, HydrantLateral, Industrial, and Irrigation.
|
|
LL_Commercial |
Commercial lateral line.
-- Description --
Lateral line that transport water to commercial facilities.
|
|
LL_Domestic |
Domestic lateral line.
-- Description --
Lateral line that transports water to domestic users.
|
|
LL_Fire |
Fire lateral line.
-- Description --
Lateral line that transports water for the purposes of distinguishing fire.
|
|
LL_HydrantLaterals |
Hydrant laterals.
-- Description --
Lateral line that transports water to the hydrants.
|
|
LL_Industrial |
Industrial lateral line.
-- Description --
Lateral line that transports water to the industrial facilities.
|
|
LL_Irrigation |
Irrigation lateral line.
-- Description --
Lateral line that transports water for the irrigation purposes.
|
|
ML |
Main line.
-- Description --
A <i>main line </i>is a large-diameter pipe that carries water from the source through the network.
|
|
ML_GM |
Main line's gravity main.
-- Description --
A <i>gravity main </i>is a type of main line that is unpressurized and relies on gravity to move the water through the main.
NOTE For the water distribution model, the types of gravity mains are Carrier, InlineStorage, and TransportPipe.
|
|
ML_GM_Carrier |
Main line's gravity main's carrier.
-- Description --
A <i>carrier pipe</i> is an inner pipe, or a hollow cylindrical tube contained inside an outer sheath. Responsible for carrying fluids, the carrier pipe runs through an outer, insulated casing that acts as a containment system that protects against spills.
|
|
ML_GM_InLineStorage |
Main line's gravity main's in-line storage.
|
|
ML_GM_TransportPipe |
Main line's gravity main's transport pipe.
|
|
ML_PM |
Main line's pressurized main.
-- Description --
A <i>pressurized main </i>is a type of main line that is pressurized.
There are numerous types of PressurizedMains in the water distribution model; they include AirRelease, BlowOff, Bypass, ChemicalInjection, DistributionMain, Interconnect, PipeBridge, SamplingStation, and TransmissionMain.
|
|
ML_PM_AirRelease |
Main line's pressurized main's air release.
|
|
ML_PM_BlowOff |
Main line's pressurized main's blow off.
|
|
ML_PM_Bypass |
Main line's pressurized main's bypass.
|
|
ML_PM_ChemicalInjection |
Main line's pressurized main's chemical injection.
|
|
ML_PM_DistributionMain |
Main line's pressurized main's distribution main.
|
|
ML_PM_Interconnect |
Main line's pressurized main's interconnect.
|
|
ML_PM_PipeBridge |
Main line's pressurized main's pipe bridge.
|
|
ML_PM_SamplingStation |
Main line's pressurized main's sampling station.
|
|
ML_PM_TransmissionMain |
Main line's pressurized main's transmission main.
|
|
ML_PM_RawWaterTransport |
|
|